the technical specifications and key engineering details for
the IntelliFlex Vertical Pumping

✅ Core Technical Specifications
•Stroke Length Range: 80–144 inches (electronically adjustable)
•Stroke Speed: 2–12 strokes per minute (SPM), software-optimized
•Polished Rod Load Capacity:
•Standard: 40,000 lbs
•Optional: 60,000 lbs
•Motor Type: Permanent Magnet Synchronous Motor (PMSM)
•Motor Power Options: 22 kW, 30 kW, 45 kW, 55 kW
•Drive System: Carbon fiber reinforced polyurethane belt with auto-tensioner
•Transmission Efficiency: ≥99.5%
•Operating Voltage: 380–600V AC, 50/60 Hz
•Ambient Temp Range: -40°C to +55°C (thermal insulation optional)
•Noise Level: ≤65 dB(A) at 10 meters
•System Height: ~4.8 meters
•Control Cabinet: IP65 rated, HMI + VFD + RTU
Product Specifications : 
  • Vertical Structure
  • Adjustable Stroke Length
  • Adjustable Stroke Frequency
  • Durable Belt
  • AC VFD Control Technology
 
 
 
🧩 System Components
•Frame: Alloy steel vertical tower, vibration-damping baseplate
•Motor Assembly: IP56 oilfield-sealed PMSM, direct-coupled (no gearbox)
•Transmission: High-durability carbon fiber belt
•Rod Suspension: Rod clamp with load cell + hydraulic buffer
•Control System: PLC + touchscreen, SCADA-ready (Modbus TCP/IP, OPC-UA optional)
•Sensors: Load, position, temperature, current, with safety shutdown
📋 Certifications
•API RP 11E
•ISO 9001, 14001, 45001
•IEC 61439
•CE Marking (on request)
•Optional: National explosion-proof (Zone 1 & 2)

🛠 Maintenance & Lifecycle
•Design Life: 10–15 years
•Maintenance intervals:
•Belt check: every 6 months
•Load cell calibration: annually
•Electrical & lubrication check: 3–12 months
•Optional remote monitoring & predictive maintenance
🔧 Customization
•Adjustable stroke length in 2” increments
•Motor and load rating configurable
•SCADA protocol and language options
•Communication: fiber, 4G/5G, satellite
•Environmental coatings for harsh climates
•Optional solar-powered UPS system